Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

German Standard (VDE) Location:Home> > English > Product Center > Mining Cables > German Standard (VDE) >

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-02-02 15:18   Browse times:second

 (N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

Applications

These cables are used for laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.

Standards

Based on VDE 0250 Part 813

Construction

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

Conductors: Flexible strandedcopper conductor, class 5 according to DIN VDE 0295.

Inner Conductor Layer: Semiconductive layer.

Insulation: EPR.

Outer Conductor Layer:Semiconductive layer.

Earth Conductor: Split intothree in the outer interstices.

InnerSheath: EPR.

  • Outer Sheath: CM.

Dimensions and Weight

3.6/6 kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 36.7 39.7 2320
3×25+3×50/3 40.6 43.6 2860
3×35+3×25/3 40.5 43.5 2860
3×35+3×50/3 42.3 45.3 3220
3×50+3×25/3 43.8 46.8 3500
3×50+3×50/3 43.8 46.8 3650
3×70+3×35/3 47.0 50.0 4360
3×70+3×50/3 49.7 53.7 5010
3×95+3×50/3 52.2 56.2 5550
3×120+3×70/3 55.9 59.9 6690
3×150+3×70/3 61.0 65.0 8030
3×185+3×95/3 64.0 68.0 9320
3×240+3×120/3 72.1 76.1 11960
3×300+3×150/3 77.3 81.3 14260

6/10 kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 39.0 42.0 2520
3×25+3×50/3 41.4 44.4 2930
3×35+3×25/3 41.8 44.8 2980
3×35+3×50/3 43.6 46.6 3350
3×50+3×25/3 45.1 48.1 3640
3×50+3×50/3 45.1 48.1 3780
3×70+3×35/3 48.3 51.3 4500
3×70+3×50/3 48.3 51.3 4730
3×95+3×50/3 53.5 57.5 5710
3×120+3×70/3 57.2 61.2 6860
3×150+3×70/3 62.3 66.3 8210
3×185+3×95/3 65.3 69.3 9510
3×240+3×120/3 73.4 77.4 12170
3×300+3×150/3 78.6 82.6 14500

8.7/15 kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 42.5 45.5 2850
3×25+3×50/3 44.2 47.2 3210
3×35+3×25/3 45.3 48.3 3340
3×35+3×50/3 45.3 48.3 3480
3×50+3×25/3 49.4 53.4 4180
3×50+3×50/3 49.4 53.4 4320
3×70+3×35/3 52.7 56.7 5090
3×70+3×50/3 52.7 56.7 5310
3×95+3×50/3 57.0 61.0 6160
3×120+3×70/3 62.1 66.1 7550
3×150+3×70/3 65.7 69.7 8710
3×185+3×95/3 68.7 72.7 10020
3×240+3×120/3 76.8 80.8 12750
3×300+3×150/3 82.0 86.0 15110

12/20 kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 45.5 48.5 3150
3×25+3×50/3 45.5 48.5 3300
3×35+3×25/3 48.3 51.3 3660
3×35+3×50/3 48.3 51.3 3800
3×50+3×25/3 52.5 56.5 4540
3×50+3×50/3 52.5 56.5 4680
3×70+3×35/3 55.7 59.7 5460
3×70+3×50/3 55.7 59.7 5690
3×95+3×50/3 61.4 65.4 6770
3×120+3×70/3 65.1 69.1 7980
3×150+3×70/3 68.7 72.7 9170
3×185+3×95/3 73.2 77.2 10780
3×240+3×120/3 79.8 83.8 13280
3×300+3×150/3 86.3 91.3 16070

14/25 kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 50.3 54.3 3750
3×25+3×50/3 50.3 54.3 3900
3×35+3×25/3 53.1 57.1 4290
3×35+3×50/3 53.1 57.1 4430
3×50+3×25/3 56.3 60.3 5020
3×50+3×50/3 56.3 60.3 5160
3×70+3×35/3 61.0 65.0 6190
3×70+3×50/3 61.0 65.0 6410
3×95+3×50/3 65.3 69.3 7340
3×120+3×70/3 69.0 73.0 8580
3×150+3×70/3 74.0 78.0 10050
3×185+3×95/3 77.0 81.0 11430
3×240+3×120/3 85.0 90.0 14400
3×300+3×150/3 90.2 95.2 16860

18/30kV

Number of Cores×Nominal Cross Section Minimium Overall Diameter Maximum Overall Diameter Nominal Weight
No.×mm² mm mm kg/km
3×25+3×25/3 53.7 57.7 4160
3×25+3×50/3 53.7 57.7 4300
3×35+3×25/3 56.6 60.6 4730
3×35+3×50/3 56.6 60.6 4870
3×50+3×25/3 61.2 65.2 5700
3×50+3×50/3 61.2 65.2 5840
3×70+3×35/3 64.4 68.4 6680
3×70+3×50/3 64.4 68.4 6900
3×95+3×50/3 68.7 72.7 7860
3×120+3×70/3 73.8 77.8 9390
3×150+3×70/3 77.5 81.5 10660
3×185+3×95/3 80.5 84.5 12060
3×240+3×120/3 88.5 93.5 15090
3×300+3×150/3 94.7 99.7 17820